DTC P281F-12: Pressure Control Solenoid "J" Circuit Short to Battery [06/2018 - 09/2024]: Description
WARNING: This page is about a different variant/trim than selected.
Using the current from the TCM, the shift solenoid valve SLP controls the primary pulley pressure in accordance with the requested gear ratio to perform gear ratio changes.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P281F-12 | Pressure Control Solenoid "J" Circuit Short to Battery | A short to +B is detected in the shift solenoid valve SLP circuit for 1 second or more (1-trip detection logic). |
|
Comes on | DTC stored | SAE Code: P2827 |