DTC P0620-49: Generator Control Circuit Internal Electronic Failure [09/2022 - 03/2023]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHARGING CIRCUIT WITHOUT LOAD
See step 6
Result
Result OK NG Result:
NG
REPAIR OR REPLACE GENERATOR ASSEMBLY
for Denso Made Generator: Refer to REMOVAL [09/2022 - 11/2022] , or refer to REMOVAL [11/2022 - 03/2023]
for VALEO Made: Refer to REMOVAL [09/2022 - 11/2022] , or refer to REMOVAL [11/2022 - ]
Result:
OK
See step 2
- CHARGING CIRCUIT WITH LOAD
See step 8
Result
Result OK NG Result:
OK
CHECK FOR INTERMITTENT PROBLEMS
Refer to CHECK FOR INTERMITTENT PROBLEMS [06/2018 - ]
Result:
NG
REPAIR OR REPLACE GENERATOR ASSEMBLY
for Denso Made Generator: Refer to REMOVAL [09/2022 - 11/2022] , or refer to REMOVAL [11/2022 - 03/2023]
for VALEO Made: Refer to REMOVAL [09/2022 - 11/2022] , or refer to REMOVAL [11/2022 - ]