DTC P0110-11: Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground [04/2018 -]: Procedure
WARNING: This page is about a different variant/trim than selected.
- READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS)
*1 Mass Air Flow Meter Sub-assembly *2 ECM - Disconnect the mass air flow meter sub-assembly connector.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / Intake Air Temperature.
Powertrain > Engine > Data List
Tester Display Intake Air Temperature - According to the display on the Techstream, read the Data List.
OK
Techstream Display Specified Condition Intake Air Temperature -40°C (-40°F) HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [04/2018 - 08/2019] , or refer to INITIALIZATION [08/2019 - 08/2021] , or refer to INITIALIZATION [08/2021 -]
Result
Proceed to OK NG
Result:
OK
REPLACE MASS AIR FLOW METER SUB-ASSEMBLY. Refer to REMOVAL [04/2018 -]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM)
- Disconnect the mass air flow meter sub-assembly connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C28-4 (THA) or C55-102 (THA) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR