Entire Combination Meter does not Operate [04/2018 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the G16 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G16-21 (ES) - Body ground Always Below 1 Ω G16-2 (EP) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition G16-39 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V G16-40 (B) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR