DTC P107A-11: Fuel Rail Pressure Sensor (Low) Circuit Short to Ground [08/2019 -]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR
*a Front view of wire harness connector
(to Fuel Pressure Sensor (for Low Pressure Side))HINT:
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
- Disconnect the fuel pressure sensor (for low pressure side) connector.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition D5-1 (VC) - D5-3 (E2) Power switch on (IG) 4.75 to 5.25 V D5-2 (PFL) - D5-3 (E2) Power switch on (IG) 4.4 to 5.6 V - Turn the power switch off and wait for at least 30 seconds.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D5-1 (VC) - D5-2 (PFL) Power switch off 171 to 189 kΩ HINT:
Perform "Inspection After Repair" after replacing the fuel pressure sensor (for low pressure side).
Refer to INITIALIZATION [08/2019 - 08/2021] , or refer to INITIALIZATION [08/2021 -]
Result
Proceed to OK NG
Result:
OK
REPLACE FUEL PRESSURE SENSOR (FOR LOW PRESSURE SIDE). Refer to REMOVAL [04/2018 - 08/2021] , or refer to REMOVAL [08/2021 -]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (FUEL PRESSURE SENSOR (FOR LOW PRESSURE SIDE) - ECM)
- Disconnect the fuel pressure sensor (for low pressure side) connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D5-1 (VC) - C55-84 (VCPF) Always Below 1 Ω D5-2 (PFL) or C55-107 (PFL) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM. Refer to REMOVAL [04/2018 - 08/2020] , or refer to REMOVAL [08/2020 - 08/2021] , or refer to REMOVAL [08/2021 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR