LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2020 >> Avalon Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 106 (Power Outlets (Interior) - Diagnostics & Circuit Tests (Hybrid)) >> WIRELESS CHARGING SYSTEM (for HV Model) >> Circuit Tests >> Wireless Charger Power Source Circuit [04/2018 - ] >> Procedure

Wireless Charger Power Source Circuit [04/2018 - ]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. CHECK HARNESS AND CONNECTOR (MOBILE WIRELESS CHARGER CRADLE ASSEMBLY POWER SOURCE) 
    1. Disconnect the G12 mobile wireless charger cradle assembly connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      G12-1 (PGND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      G12-6 (B+) - Body ground Power switch off 11 to 14 V
      G12-5 (ACC) - Body ground Power switch on (ACC) 11 to 14 V

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [04/2018 - ]  

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR