Typical Enabling Conditions
WARNING: This page is about a different car, the 2021 Toyota Avalon. However, it is still accessible from the selected car via links, so may be relevant.
| All of the following conditions are met |
- |
| Battery voltage |
8 V or higher |
| Engine switch |
On (IG) |
| Time after engine switch off to on (IG) |
0.5 seconds or more |
| Output duty cycle |
30 to 85% |
| Starter |
Off |
| Engine water pump circuit pulse input fail (P26CA) |
Not detected |