LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2019 >> Sienna SE, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 6 (Automatic Transaxle System [U660E] (Service Information)) >> VALVE BODY ASSEMBLY(When Not Using the Engine Support Bridge) >> Inspection [12/2015 - 08/2016] >> Procedure

Inspection [12/2015 - 08/2016]: Procedure

WARNING: This page is about a different car, the 2016 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT SHIFT SOLENOID VALVE SL 
    1. Measure the resistance according to the value(s) in the table below.
      GTY312939Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Shift Solenoid Valve SL)

      Standard Resistance

      Tester Connection Condition Specified Condition
      Solenoid Connector - Solenoid Body 20°C (68°F) 11 to 15 Ω
      1. If the result is not as specified, replace the shift solenoid valve SL.
    2. Connect a battery positive (+) lead to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating sound.
      NOTE:

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK

      Valve moves and makes an operating sound.

      1. If the result is not as specified, replace the shift solenoid valve SL.
  2. INSPECT SHIFT SOLENOID VALVE SLT 
    1. Measure the resistance according to the value(s) in the table below.
      GTY310999Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *a Component without harness connected
      (Shift Solenoid Valve SLT)

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the result is not as specified, replace the shift solenoid valve SLT.

    2. Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
      NOTE:

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK

      Valve moves and makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SLT.

  3. INSPECT SHIFT SOLENOID VALVE SLU 

    HINT: 

    Refer to Inspect Shift Solenoid Valve SLT.

  4. INSPECT SHIFT SOLENOID VALVE SL1 

    HINT: 

    Refer to Inspect Shift Solenoid Valve SLT.

  5. INSPECT SHIFT SOLENOID VALVE SL2 

    HINT: 

    Refer to Inspect Shift Solenoid Valve SLT.

  6. INSPECT SHIFT SOLENOID VALVE SL3 

    HINT: 

    Refer to Inspect Shift Solenoid Valve SLT.

  7. INSPECT SHIFT SOLENOID VALVE SL4 

    HINT: 

    Refer to Inspect Shift Solenoid Valve SLT.