Inspection [12/2015 - 08/2016]: Procedure
WARNING: This page is about a different car, the 2016 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
- INSPECT KNOCK SENSOR
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component without harness connected
(Knock Sensor)Standard Resistance
Tester Connection Condition Specified Condition 1 (Ground) - 2 (Output) 20°C (68°F) 120 to 280 kΩ If the result is not as specified, replace the knock sensor.
- Measure the resistance according to the value(s) in the table below.