Monitor Description
This monitor will run when the engine is started at an engine coolant temperature of -10 to 50°C (14 to 122°F). The DTC is stored after the engine idles for 13 seconds (2 trip detection logic).
The DTC is designed to monitor the ignition timing at cold start. When the engine is started at an engine coolant temperature of less than 50°C (122°F), the ECM checks the ignition timing during engine idling. If the ignition timing advances beyond the specified level within 10 seconds, the ECM interprets this as a malfunction. The MIL is illuminated and a DTC is stored when the malfunction is detected in consecutive driving cycles (2 trip detection logic).
When learning value reset and idle learning after inspections or repairs, the idle speed control learned values are cleared. This DTC cannot be stored with the idle speed control learned values cleared.
HINT:
Idle speed control learning is performed when the engine is warmed up and has been idling for 5 minutes.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P050B | Insufficient ignition timing retard at cold start (2 trip detection logic). |
|