Home >> Toyota >> 2019 >> Sienna SE, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 16 (Engine Control System [2GR-FE] - Diagnostic Codes (1 Of 3)) >> SFI System >> DTC P0111: Intake Air Temperature Sensor 1 Circuit Range / Performance [12/2015 - 08/2016] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2016 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
ALL

Monitor runs whenever following DTCs are not present None
AFTER ENGINE STOP

All of the following conditions are met -
Time after engine start 10 seconds or more
Battery voltage 10.5 V or higher
Engine coolant temperature at ECM started by internal engine off timer -40°C (-40°F) or higher
Engine coolant temperature before engine stop 70°C (158°F) or higher
Time that mass air flow is low before engine stop 35 minutes or more
Accumulated mass air flow amount in previous driving cycle 2906 g or more
Key off duration 30 minutes
Intake air temperature sensor circuit fail (P0112, P0113) Not detected
Engine coolant temperature sensor circuit fail (P0115, P0117, P0118) Not detected
Mass air flow sensor circuit fail (P0102, P0103) Not detected
AFTER COLD ENGINE START

All of the following conditions are met -
Key-off duration 5 hours or more
Time after engine start 10 seconds or more
Engine coolant temperature 70°C (158°F) or more
Accumulated mass air flow amount 2906 g or more
One of the following conditions 1 or 2 is met: -
1. Duration while engine load is low 120 seconds or more
2. Duration while engine load is high 10 seconds or more
Intake air temperature sensor circuit fail (P0112, P0113) Not detected
Engine coolant temperature sensor circuit fail (P0115, P0117, P0118) Not detected
Mass air flow sensor circuit fail (P0102, P0103) Not detected