LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2019 >> Sienna SE, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 16 (Engine Control System [2GR-FE] - Diagnostic Codes (1 Of 3)) >> SFI System >> DTC P0013: Camshaft Position "B" Actuator Circuit / Open (Bank 1); DTC P0023: Camshaft Position "B" Actuator Circuit / Open (Bank 2) [12/2015 - 08/2016] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2016 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
ALL

Monitor runs whenever following DTCs are not present None
All of the following conditions are met: -
Starter OFF
Ignition switch ON
Time after ignition switch off to ON 0.5 seconds or more
CASE 1

One of the following conditions is met Conditions A or B
A. All of the following conditions are met -
Battery voltage 11 V or higher, and less than 13 V
Target duty cycle Less than 70%
B. All of the following conditions are met -
Battery voltage 13 V or higher
Target duty cycle Less than 80%
CASE 2

Current cut status Not cut