Home >> Toyota >> 2019 >> Sienna SE, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 13 (Engine Control System [2GR-FE] - Diagnostic Codes (3 Of 3) & Circuit Tests) >> SFI System >> DTC P2420: Evaporative Emission Pressure Switching Valve Stuck OFF [12/2015 - 08/2016] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2016 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
Monitor runs whenever following DTCs not stored None
Atmospheric pressure 70 to 110 kPa(abs) [525 to 825 mmHg(abs)]
Battery voltage 10.5 V or higher
Vehicle speed Less than 4 km/h (2.5 mph)
Ignition switch OFF
Time after key-off 5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions met before key-off Conditions 1 and 2
1. Duration that vehicle is driven 5 minutes or more
2. EVAP purge operation Performed
Engine coolant temperature 4.4 to 35°C (40 to 95°F)
Intake air temperature 4.4 to 35°C (40 to 95°F)