LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2019 >> Sienna Limited, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 5 (Automatic Transaxle System [UA80E] - Diagnostic Codes (1 Of 3)) >> Automatic Transaxle System >> DTC P0740-11: Torque Converter Clutch Circuit Short to Ground [11/2017 - ] >> Procedure

DTC P0740-11: Torque Converter Clutch Circuit Short to Ground [11/2017 - ]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL) 
    1. Disconnect the B65 transmission wire connector.
      GTY730438Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component without harness connected
      (Transmission Wire)
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      13 (SL) - Body ground 20°C (68°F) 11 to 15 Ω
    3. Connect the B65 transmission wire connector.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    See step  4

    Result: 

    OK 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) 
    1. Disconnect the B67 ECM connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      B67-62 (SL) - Body ground 20°C (68°F) 11 to 15 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  3

  3. REPLACE ECM 

    Refer to COMPONENTS [08/2016 - ]

    Result

    Proceed to
    NEXT

    Result: 

    NEXT 

    PERFORM A/T CODE REGISTRATION. Refer to  REGISTRATION [08/2016 - ] 

  4. INSPECT SHIFT SOLENOID VALVE SL 
    1. Remove the shift solenoid valve SL.

      Refer to DISASSEMBLY [08/2016 - ]

      GTY720882Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 Shift Solenoid Valve SL
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω
    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating sound.

      OK

      Measurement Condition Specified Condition
      • Battery positive (+) → Shift solenoid valve SL connector
      • Battery negative (-) → Shift solenoid valve SL body
      Valve moves and makes an operating sound

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE TRANSMISSION WIRE. Refer to  COMPONENTS [08/2016 - ] 

    Result: 

    NG 

    REPLACE SHIFT SOLENOID VALVE SL. Refer to  COMPONENTS [08/2016 - ]