DTC C1746: Gate Solenoid Valve Circuit Malfunction [08/2015 - 08/2019]: Description
The suspension control ECU opens the gate solenoid valve (No. 2 height control valve) to lead the compressed air to the height control cylinder (pneumatic cylinder) and to raise the vehicle height.
Further, the gate solenoid valve (No. 2 height control valve) opens and closes the passage between the right and left height control cylinders (pneumatic cylinders).
The No. 2 height control valve consists of a leveling solenoid valve and a gate solenoid valve.
The gate solenoid valve opens and closes the passage between the compressor and the height control cylinder (pneumatic cylinder).
| DTC Code | Detection Condition | Trouble Area |
|---|---|---|
| C1746 | When either of the following is detected:
|
|
HINT:
- Once the ECU stores DTC C1746 in the memory, the vehicle height control is suspended until a normal signal is input to the ECU from the height control solenoid valves. However, control is resumed if the ignition switch is turned off, then to ON again.
- Malfunction in the gate solenoid valve:
The height control operation is suspended, and the height control indicator light does not change by operating the height control switch.