Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
ALL
| The monitor will run whenever the following DTCs are not present | P0717 (Turbine speed sensor circuit) P0722 (Output speed sensor circuit) P0973, P0974 (Shift solenoid valve S1 circuit) P0976, P0977 (Shift solenoid valve S2 circuit) P0761, P0979, P0980 (Shift solenoid valve S3 circuit) P0766, P0982, P0983 (Shift solenoid valve S4 circuit) P0985, P0986 (Shift solenoid valve SR circuit) P2759 (Torque converter clutch pressure control solenoid circuit) P0327, P0328, P032C, P032D, P0332, P0333, P033C, P033D (KCS sensor circuit) P0778 (Shift solenoid valve SL2 circuit) P0781 (1 - 2 shift valve) P0729 (Reverse sequence valve) |
| ETCS (Electric Throttle Control System) | Not system down |
| Transmission position | "D" |
| Duration time from shifting "N" to "D" | 4 seconds or more |
| ECT (Engine coolant temperature) | 40°C (104°F) or higher |
| Spark advance from max. retard timing by KCS control | 0° crankshaft angle or more |
| Engine | Starting |
| ECM selected gear | 2nd, 3rd, 4th, 5th or 6th |
| Vehicle speed | 25 km/h (15.5 mph) or more |
OFF MALFUNCTION (A)
| ECM lock-up command | ON (SLU pressure: 513 kPa (5.2 kgf/cm2 , 74 psi) or higher) |
| Duration time from lock-up on command | 3 seconds or more |
| Input speed/output speed (NT/NO) NT: Input (Turbine) speed NO: Internal counter shaft speed |
0.66 to 0.80 or 0.51 to 0.65 |
| Calculated load value | A/C off: 17.4% or more when turbine speed is 375 RPM A/C on: 18.6% or more when turbine speed is 375 RPM (Conditions vary with turbine speed) |
| Vehicle speed | Less than 120 km/h (74.6 mph) |
OFF MALFUNCTION (B)
| ECM selected gear | 2nd |
| Vehicle speed | 2 km/h (1.2 mph) or more |
| Output speed | 2nd → 1st down-shift point or more |
| Throttle valve opening angle | 9% or more at 2000 RPM (Conditions vary with engine speed) |
| Calculated load value | 7.75% or more (A/C off) 7.75% or more (A/C on) |
| Input speed/output speed (NT/NO) NT: Input (Turbine) speed NO: Internal counter shaft speed |
3.11 to 7.58 or 1.83 to 2.27 or 1.24 to 1.49 or 0.93 to 1.07 or 0.66 to 0.80 or 0.51 to 0.65 |
ON MALFUNCTION
| ECM lock-up command | OFF (SLU pressure: Below 4 kPa (0.04 kgf/cm2 , 0.6 psi)) |
| Duration time from lock-up off command | 3 seconds or more |
| Throttle valve opening angle | 6% or more |
| Input speed/output speed (NT/NO) NT: Input (Turbine) speed NO: Internal counter shaft speed |
1.83 to 2.27 or 1.24 to 1.49 or 0.93 to 1.07 or 0.66 to 0.80 or 0.51 to 0.65 |
| Calculated load value | A/C off: 17.4% or more when turbine speed is 375 RPM A/C on: 18.6% or more when turbine speed is 375 RPM (Conditions vary with turbine speed) |
| Vehicle speed | Less than 120 km/h (74.6 mph) |