Inspection [08/2015 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition - 2 (RB) - 6 (PL)
- 4 (B) - 5 (L)
Shift lever in P Below 1 Ω 2 (RB) - 1 (RL) Shift lever in R Below 1 Ω - 2 (RB) - 9 (NL)
- 4 (B) - 5 (L)
Shift lever in N Below 1 Ω 2 (RB) - 7 (DL) - Shift lever in D
- Shift lever in S, "+" and "-"
Below 1 Ω - 2 (RB) - 6 (PL)
- 4 (B) - 5 (L)
Shift lever not in P 10 kΩ or higher 2 (RB) - 1 (RL) Shift lever not in R 10 kΩ or higher - 2 (RB) - 9 (NL)
- 4 (B) - 5 (L)
Shift lever not in N 10 kΩ or higher 2 (RB) - 7 (DL) - Shift lever not in D
- Shift lever not in S, "+" and "-"
10 kΩ or higher If the result is not as specified, replace the switch assembly.
- Measure the resistance according to the value(s) in the table below.