Sound Signal Circuit between Headphone Terminal and Television Display [08/2015 - 08/2019]: Procedure
- CHECK HEADPHONES
- Check the malfunctioning headphones.RESULT
Result Proceed to Malfunction in headphone terminal RH side A Malfunction in headphone terminal LH side B
Result:
B
See step 4
Result:
A
See step 2
- Check the malfunctioning headphones.
- CHECK HARNESS AND CONNECTOR (TELEVISION DISPLAY ASSEMBLY - HEADPHONE TERMINAL RH)
- Disconnect the U13 television display assembly connector.
- Disconnect the S7 headphone terminal RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition U13-26 (HP2R) - S7-1 (HP2R) Always Below 1 Ω U13-28 (HP2L) - S7-2 (HP2L) Always Below 1 Ω U13-27 (SLD6) - S7-3 (SG8) Always Below 1 Ω U13-26 (HP2R) - Body ground Always 10 kΩ or higher U13-28 (HP2L) - Body ground Always 10 kΩ or higher U13-27 (SLD6) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- CHECK TELEVISION DISPLAY ASSEMBLY
- Remove the television display assembly connector still connected (Refer to REMOVAL [08/2015 - 08/2019]
).
- Using an oscilloscope, check the waveform between each terminal and the body ground according to the conditions as shown in the table below.
Standard
Tester Connection Condition Specified Condition U13-26 (HP2R) - Body ground Audio sound being produced A waveform synchronized with sound is output U13-28 (HP2L) - Body ground TEXT IN ILLUSTRATION*a Component with harness connected
(Television Display Assembly)
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(Refer to PROBLEM SYMPTOMS TABLE [08/2015 - 08/2019] )
Result:
NG
REPLACE TELEVISION DISPLAY ASSEMBLY
(Refer to REMOVAL [08/2015 - 08/2019] )
- Remove the television display assembly connector still connected (Refer to REMOVAL [08/2015 - 08/2019]
).
- CHECK HARNESS AND CONNECTOR (TELEVISION DISPLAY ASSEMBLY - HEADPHONE TERMINAL LH)
- Disconnect the U13 television display assembly connector.
- Disconnect the S8 headphone terminal LH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition U13-12 (HP1R) - S8-1 (HP1R) Always Below 1 Ω U13-14 (HP1L) - S8-2 (HP1L) Always Below 1 Ω U13-13 (SLD5) - S8-3 (SG7) Always Below 1 Ω U13-12 (HP1R) - Body ground Always 10 kΩ or higher U13-14 (HP1L) - Body ground Always 10 kΩ or higher U13-13 (SLD5) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- CHECK TELEVISION DISPLAY ASSEMBLY
- Remove the television display assembly connector still connected (Refer to REMOVAL [08/2015 - 08/2019]
).
- Using an oscilloscope, check the waveform between each terminal and the body ground according to the conditions as shown in the table below.
Standard
Tester Connection Condition Specified Condition U13-12 (HP1R) - Body ground Audio sound being produced A waveform synchronized with sound is output U13-14 (HP1L) - Body ground TEXT IN ILLUSTRATION*a Component with harness connected
(Television Display Assembly)
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(Refer to PROBLEM SYMPTOMS TABLE [08/2015 - 08/2019] )
Result:
NG
REPLACE TELEVISION DISPLAY ASSEMBLY
(Refer to REMOVAL [08/2015 - 08/2019] )
- Remove the television display assembly connector still connected (Refer to REMOVAL [08/2015 - 08/2019]
).