Home >> Toyota >> 2019 >> Sequoia SR5, 4WD >> Repair and Diagnosis >> Accessories & Equipment >> Infotainment >> Rear Seat Entertainment System - Diagnostic Codes & Symptom Tests >> Rear Seat Entertainment System >> Mute Signal Circuit between Radio Receiver and Television Display Assembly [08/2019 - ] >> Procedure

Mute Signal Circuit between Radio Receiver and Television Display Assembly [08/2019 - ]: Procedure

  1. INSPECT TELEVISION DISPLAY ASSEMBLY 
    1. Measure the voltage according to the value(s) in the table below.
      GTY878847Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Component with harness connected
      (Television Display Assembly)

      Standard Voltage

      Tester Connection Condition Specified Condition
      U13-6 (MUT1) - Body ground Engine switch on (ACC)
      RSE system playing
      → Changing source
      3.5 V or higher
      → Below 1 V

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [08/2019 - ] 

    Result: 

    NG 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (RADIO AND DISPLAY RECEIVER ASSEMBLY - TELEVISION DISPLAY ASSEMBLY) 
    1. Disconnect the U13 television display assembly connector.
    2. Disconnect the H203 radio and display receiver assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      U13-6 (MUT1) - H203-12 (MUTE) Always Below 1 Ω
      U13-6 (MUT1) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  3

  3. REPLACE TELEVISION DISPLAY ASSEMBLY 
    1. Replace the television display assembly and check if it operates normally.

      Refer to REMOVAL [08/2019 - ]

      OK

      The rear seat entertainment system operates normally.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    END (TELEVISION DISPLAY ASSEMBLY WAS DEFECTIVE) 

    Result: 

    NG 

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [08/2019 - ]