Hazard Warning Switch Circuit [08/2017 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [08/2017 - 08/2019] , or refer to DATA LIST / ACTIVE TEST [08/2019 - ]
COMBINATION METERTester Display Measurement Item / Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch assembly / OFF or ON OFF: Hazard warning signal switch assembly off
ON: Hazard warning signal switch assembly on- OK
Normal condition listed above is displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [08/2017 - 08/2019] , or refer to PROBLEM SYMPTOMS TABLE [08/2019 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
- Remove the hazard warning signal switch assembly.
Refer to REMOVAL [08/2017 - ]
- Inspect the hazard warning signal switch assembly.
Refer to INSPECTION [08/2015 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY. Refer to REMOVAL [08/2017 - ]
Result:
OK
See step 3
- Remove the hazard warning signal switch assembly.
- CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the H136 hazard warning signal switch assembly connector.
- Disconnect the H139 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H139-20 (HAZ) - H136-4 (B1) Always Below 1 Ω H139-1 (E) - Body ground Always Below 1 Ω H139-20 (HAZ) or H136-4 (B1) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [08/2017 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR