Inspection [11/2018 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY
- Inspect SMRB:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(HV Battery Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition z22-1 (+) - Y3-1 (CBI) Auxiliary battery voltage not applied between terminals M32-1 (SMRB) and M32-3 (GND) 10 kΩ or higher z22-1 (+) - Y3-1 (CBI) Auxiliary battery voltage applied between terminals M32-1 (SMRB) and M32-3 (GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M32-1 (SMRB) - M32-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω If the result is not as specified, replace the HV battery junction block assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRG:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(HV Battery Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage not applied between terminals M32-4 (SMRG) and M32-3 (GND) 10 kΩ or higher z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage applied between terminals M32-4 (SMRG) and M32-3 (GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M32-4 (SMRG) - M32-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω If the result is not as specified, replace the HV battery junction block assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRP:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(HV Battery Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage not applied between terminals M32-2 (SMRP) and M32-3 (GND) 10 kΩ or higher z21-1 (-) - Y4-1 (CEI) Auxiliary battery voltage applied between terminals M32-2 (SMRP) and M32-3 (GND) 24.3 to 29.7 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M32-2 (SMRP) - M32-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω If the result is not as specified, replace the HV battery junction block assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRB: