A/C Switch Indicator does not Turn On [02/2019 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK MALFUNCTION STATUS
- Check the malfunction status of switch indicators on the air conditioning control assembly.
Result
Result Proceed to A/C switch indicators are not always illuminated A A/C switch indicators are not illuminated only immediately after starting the hybrid control system B
Result:
B
GO TO INITIALIZATION. Refer to INITIALIZATION [02/2019 - ]
Result:
A
See step 2
- Check the malfunction status of switch indicators on the air conditioning control assembly.
- READ VALUE USING TECHSTREAM (AMBIENT TEMP SENSOR)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed Thermistor assembly system malfunction - When open circuit: -23.30°C (-9.94°F)
- When short circuit: 65.95°C (150.71°F)
Body Electrical > Air Conditioner > Data List
Tester Display Ambient Temp Sensor OK
The display is as specified in the normal condition column (0°C (32°F) or higher).
Result
Proceed to OK NG
Result:
OK
GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE). Refer to PROCEDURE - Step 2
Result:
NG
GO TO AMBIENT TEMPERATURE DISPLAY SYSTEM. Refer to Ambient Temperature Display System [02/2019 - 06/2020] , or refer to Ambient Temperature Display System [06/2020 - 08/2020] , or refer to Ambient Temperature Display System [08/2020 - ]