LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2019 >> RAV4 XLE, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 61 (Heating / Air Conditioning System (HV) - Diagnostic Codes (1 Of 3)) >> AIR CONDITIONING SYSTEM (for HV Model) >> DTC B1411: Room Temperature Sensor Circuit [11/2018 - 02/2019] >> Procedure

DTC B1411: Room Temperature Sensor Circuit [11/2018 - 02/2019]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. READ VALUE USING TECHSTREAM (ROOM TEMPERATURE SENSOR) 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.
    5. Read the Data List according to the display on the Techstream.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler thermistor (room temperature sensor) Min.: -6.50°C (20.30°F)
      Max.: 57.25°C (135.05°F)
      Actual cabin temperature displayed Cooler thermistor (room temperature sensor) system malfunction
      • When open circuit: -6.50°C (20.30°F)
      • When short circuit: 57.25°C (135.05°F)

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Room Temperature Sensor

      OK

      The display is as specified in the normal condition column.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [11/2018 - ] 

    Result: 

    NG 

    See step  2

  2. INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) 
    1. Remove the cooler thermistor (room temperature sensor).

      Refer to REMOVAL [11/2018 - 02/2019]

    2. Inspect the cooler thermistor (room temperature sensor).

      Refer to INSPECTION [11/2018 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR). Refer to  REMOVAL [11/2018 - 02/2019] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)) 
    1. Disconnect the G47 air conditioning amplifier assembly connector.
    2. Disconnect the G60 cooler thermistor (room temperature sensor) connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      G47-5 (TR) - G60-1 Always Below 1 Ω
      G47-3 (SG-1) - G60-2 Always Below 1 Ω
      G47-5 (TR) or G60-1 - Other terminals and body ground Always 10 kΩ or higher
      G47-3 (SG-1) or G60-2 - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [11/2018 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR