DTC B1411: Room Temperature Sensor Circuit [02/2019 - ]: Procedure
- READ VALUE USING TECHSTREAM (ROOM TEMPERATURE SENSOR)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Room Temperature Sensor Cooler thermistor (room temperature sensor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)Actual cabin temperature displayed Cooler thermistor (room temperature sensor) system malfunction - When open circuit: -6.50°C (20.30°F)
- When short circuit: 57.25°C (135.05°F)
Body Electrical > Air Conditioner > Data List
Tester Display Room Temperature Sensor OK
The display is as specified in the normal condition column.
Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2018 - ]
Result:
NG
See step 2
- INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
- Remove the cooler thermistor (room temperature sensor).
Refer to REMOVAL [02/2019 - 10/2019] , or refer to REMOVAL [10/2019 - 08/2020] , or refer to REMOVAL [08/2020 - 12/2021] , or refer to REMOVAL [12/2021 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023] , or refer to REMOVAL [10/2023 - ]
- Inspect the cooler thermistor (room temperature sensor).
Refer to INSPECTION [11/2018 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR). Refer to REMOVAL [02/2019 - 10/2019] , or refer to REMOVAL [10/2019 - 08/2020] , or refer to REMOVAL [08/2020 - 12/2021] , or refer to REMOVAL [12/2021 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023] , or refer to REMOVAL [10/2023 - ]
Result:
OK
See step 3
- Remove the cooler thermistor (room temperature sensor).
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR (ROOM TEMPERATURE SENSOR))
- Disconnect the G47 air conditioning amplifier assembly connector.
- Disconnect the G60 cooler thermistor (room temperature sensor) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G47-5 (TR) - G60-1 Always Below 1 Ω G47-3 (SG-1) - G60-2 Always Below 1 Ω G47-5 (TR) or G60-1 - Other terminals and body ground Always 10 kΩ or higher G47-3 (SG-1) or G60-2 - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2018 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR