Caution / Notice / Hint
WARNING: This page is about a different variant/trim than selected.
NOTE:
- First perform the communication function inspections in How to Proceed with Troubleshooting to confirm that there are no CAN communication malfunctions before troubleshooting this problem.
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2018 - 10/2023]
- Inspect fuses for circuits related to this system before performing the following inspection procedure.
- This check is possible only when the power back door function customization setting using the multi-information display in the combination meter assembly is set to ON (initial setting is ON).
- If the replacement, removal and installation of the multiplex network door ECU or disconnection of the connectors of the multiplex network door ECU has been performed, initialize the power back door system.
Refer to INITIALIZATION [11/2018 - 10/2023]
- If the 2-step unlock function is enabled via customize settings, only the driver door unlocks when the first unlock operation is performed and the power back door does not operate as all the doors are not unlocked.