Removal [11/2018 - 02/2019]: Procedure
WARNING: This page is about a different variant/trim than selected.
- DRAIN COOLANT (for Inverter)
Refer to PROCEDURE - Step 1
- REMOVE UPPER RADIATOR SUPPORT SUB-ASSEMBLY
Refer to REMOVAL [11/2018 - 02/2019]
- REMOVE RADIATOR ASSEMBLY (for Inverter Coolant)
- Slide the 2 hose clips and disconnect the No. 3 inverter cooling hose and No. 4 inverter cooling hose from the radiator assembly.
*1 No. 3 Inverter Cooling Hose *2 No. 4 Inverter Cooling Hose - Remove the 4 bolts.
- Detach the 2 claws and remove the radiator assembly.NOTE:
- Put pieces of cloth into the pipes and disconnected hoses or cover the pipes and hoses with plastic bags to prevent foreign matter from entering the radiator assembly and cooling system.
- Do not apply excessive force to the No. 3 inverter cooling hose and No. 4 inverter cooling hose.
- Slide the 2 hose clips and disconnect the No. 3 inverter cooling hose and No. 4 inverter cooling hose from the radiator assembly.