Home >> Toyota >> 2019 >> RAV4 XLE, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 33 (Engine Control System (A25A-FXS) - Diagnostic Codes (07 Of 11)) >> SFI System >> DTC P0597-14: Thermostat Heater Control Circuit Short to Ground or Open [08/2020 - 12/2021] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2025 Toyota RAV4, 2024 Toyota RAV4, 2023 Toyota RAV4, 2022 Toyota RAV4, and 2021 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.
Monitor runs whenever the following DTCs are not stored None
All of the following conditions are met -
Either of the following conditions is met 1 or 2
1. Both of the following conditions are met (a) and (b)
(a) Last thermostat heater output terminal voltage level Low
(b) Current thermostat heater output terminal voltage level Low
2. Both of the following conditions are met (c) and (d)
(c) Last thermostat heater output terminal voltage level High
(d) Current thermostat heater output terminal voltage level High
Auxiliary battery voltage 8 V or higher
Command to thermostat heater Off