Inspection [12/2021 - ]: Procedure
- INSPECT ST NO. 1 RELAY (STARTER RELAY ASSEMBLY)
- Check the resistance.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher Battery voltage applied to terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the ST No. 1 relay.
- Measure the resistance according to the value(s) in the table below.
- Check the resistance.