Home >> Toyota >> 2019 >> RAV4 LE, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 136 (Automatic Transaxle System (UB80F) - Diagnostic Codes (3 Of 3) & Circuit Tests) >> Automatic Transaxle System >> DTC P2713-7F: Pressure Control Solenoid "D" Actuator Stuck Off [11/2018 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different variant/trim than selected.

ON malfunction 

  1. Any of the following conditions are met: ON malfunction (A), (B), (C), (D), (E), (F), (G), (H), (I), (J), (K), (L), (M), (N), (O), (P), (Q), (R) or (S)
    ON MALFUNCTION (A)

    Summation of clutch heat generations at 1st gear (J1summax) Specified value
    ON MALFUNCTION (B)

    Summation of clutch heat generations at 2nd gear (J2summax) Specified value
    ON MALFUNCTION (C)

    Summation of clutch heat generations at 3rd gear (J3summax) Specified value
    ON MALFUNCTION (D)

    Summation of clutch heat generations at 4th gear (J4summax) Specified value
    ON MALFUNCTION (E)

    Summation of clutch heat generations at 5th gear (J5summax) Specified value
    ON MALFUNCTION (F)

    Summation of clutch heat generations at 6th gear (J6summax) Specified value
    ON MALFUNCTION (G)

    Summation of clutch heat generations at 7th gear (J7summax) Specified value
    ON MALFUNCTION (H)

    Summation of clutch heat generations at 8th gear (J8summax) Specified value
    ON MALFUNCTION (I)

    Solenoid (SL1) valve ON malfunction
    ON MALFUNCTION (J) AND (K)

    Solenoid (SL3) valve ON malfunction
    ON MALFUNCTION (L)

    Solenoid (SL4) valve ON malfunction
    ON MALFUNCTION (M)

    Solenoid (SLU) valve OFF malfunction
    ON MALFUNCTION (N), (O), (P), (Q), (R) AND (S)

    Neutral state flag ON

OFF malfunction 

  1. Any of the following conditions are met (a) or (b)
    (a) Turbine speed/Output speed (NT/NO) 1.129 or more and 1.308 or less
    (When output speed less than 570 rpm)
    (b) Turbine speed - Output speed x 5th gear ratio -50 rpm or more and 50 rpm or less
    (When output speed 570 rpm or more)

HINT: 

NEUTRAL STATE FLAG:

Turbine speed - output speed x (ECM selected gear ratio) 1000 rpm or more