Home >> Toyota >> 2019 >> RAV4 LE, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 58 (Hybrid Battery System (Lithium-Ion Battery) - Diagnostic Codes (1 Of 3)) >> HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY) >> DTC P0A81-11: Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground; DTC P0A81-4B: Hybrid/EV Battery Cooling Fan 1 Over Temperature [06/2020 - ] >> Description

DTC P0A81-11: Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground; DTC P0A81-4B: Hybrid/EV Battery Cooling Fan 1 Over Temperature [06/2020 - ]: Description

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2025 Toyota RAV4, 2024 Toyota RAV4, 2023 Toyota RAV4, 2022 Toyota RAV4, and 2021 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.

The battery cooling blower assembly speed is controlled by the battery ECU assembly. Power is supplied to the battery cooling blower assembly when the MREL terminal of the hybrid vehicle control ECU assembly turns on the IGCT relay. The battery ECU assembly sends command signals (SI0) to the battery cooling blower assembly to adjust the fan speed to an appropriate speed for the HV battery temperature. The frequency (FP0) of the battery cooling blower assembly is sent to the battery ECU assembly as a monitor signal.

GTY588253Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A81-11 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground Both of the following conditions are met:
  • The speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range.
  • The battery cooling blower assembly speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking).

(2 trip detection logic)
  • Battery cooling blower assembly
  • Battery ECU assembly
  • BATT FAN fuse
  • Wire harness or connector
Comes on Master Warning:
Comes on
P0A81-4B Hybrid/EV Battery Cooling Fan 1 Over Temperature Both of the following conditions are met:
  • The HV battery temperature is high and the speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range.
  • The HV battery temperature is high and the battery cooling blower assembly speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking).

(1 trip detection logic)
  • Battery cooling blower assembly
  • Battery ECU assembly
  • BATT FAN fuse
  • Wire harness or connector
Comes on Master Warning:
Comes on
RELATED DATA LIST

DTC No. Data List
P0A81-11
  • Hybrid/EV Battery Cooling Fan 1 Drive Request
  • Hybrid/EV Battery Cooling Fan 1 Drive Status
  • Hybrid/EV Battery Cooling Fan 1 Frequency
P0A81-4B

The following items can be helpful when performing repairs:

Data List 

HINT: 

"Hybrid/EV Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly speed.