On-Vehicle Inspection [06/2015 - ]: Procedure
- INSPECT RADIATOR FAN RELAY
- Check the radiator fan relay (RDI FAN NO. 1) resistance.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the radiator fan relay.
- Measure the resistance according to the value(s) in the table below.
- Check the radiator fan relay (RDI FAN NO. 1) resistance.
- INSPECT NO. 2 RADIATOR FAN RELAY
- Check the No. 2 radiator fan relay (RDI FAN NO. 2) resistance.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 2 radiator fan relay.
- Measure the resistance according to the value(s) in the table below.
- Check the No. 2 radiator fan relay (RDI FAN NO. 2) resistance.