Inspection [06/2015 - ]: Procedure
- INSPECT HIGH PITCHED HORN ASSEMBLY
- Check the operation.
- Apply auxiliary battery voltage to the terminal 1 and the body ground, and check that the horn sounds.
*a Component without harness connected
(High Pitched Horn Assembly)*b Auxiliary battery *c Body Ground OK
Measurement Condition Specified Condition Auxiliary battery positive (+) - Terminal 1 Horn sounds Auxiliary battery negative (-) - Body ground If the result is not as specified, replace the high pitched horn assembly.
- Apply auxiliary battery voltage to the terminal 1 and the body ground, and check that the horn sounds.
- Check the operation.
- INSPECT LOW PITCHED HORN ASSEMBLY
- Check the operation.
- Apply auxiliary battery voltage to the terminal 1 and the body ground, and check that the horn sounds.
OK
Measurement Condition Specified Condition Auxiliary battery positive (+) - Terminal 1 Horn sounds Auxiliary battery negative (-) - Body ground *a Component without harness connected
(Low Pitched Horn Assembly)*b Auxiliary battery *c Body Ground If the result is not as specified, replace the low pitched horn assembly.
- Apply auxiliary battery voltage to the terminal 1 and the body ground, and check that the horn sounds.
- Check the operation.