Inspection [06/2015 - ]: Procedure
- INSPECT FUEL LID OPNER RELAY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 4 Auxiliary battery voltage applied to terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied to terminals 1 and 2 Below 1 Ω 3 - 4 Auxiliary battery voltage not applied to terminals 1 and 2 Below 1 Ω 3 - 5 Auxiliary battery voltage not applied to terminals 1 and 2 10 kΩ or higher - If the result is not as specified, replace the fuel lid opener relay.
- Measure the resistance according to the value(s) in the table below.