Inspection [06/2015 - ]: Procedure
- INSPECT LUGGAGE DOOR OPENING CANCEL SWITCH ASSEMBLY
- Check the resistance.
*a Component without harness connected
(Luggage Door Opening Cancel Switch Assembly)*b Cancel Switch - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Switch off (Not pressed) 10 kΩ or higher Switch on (Pressed) Below 1 Ω - If the result is not as specified, replace the luggage door opening cancel switch assembly.
- Measure the resistance according to the value(s) in the table below.
- Check the resistance.