Data List / Active Test [11/2018 - ]
- DATA LIST NOTE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Central Gateway / Data List.
Body Electrical > Central Gateway > Data List
Tester Display IG2 SW IG1 SW ACC SW +B Voltage Number of DTC - According to the display on the Techstream, read the Data List.
Body Electrical > Central Gateway > Data List
Tester Display Measurement Item Range Normal Condition IG2 SW Power switch on (IG) signal (IG2 terminal) OFF or ON OFF: Power switch on (ACC) or off
ON: Power switch on (IG)IG1 SW Power switch on (IG) signal (IG1 terminal) OFF or ON OFF: Power switch on (ACC) or off
ON: Power switch on (IG)ACC SW Power switch on (ACC) signal (ACC terminal) OFF or ON OFF: Power switch off
ON: Power switch on (ACC) or on (IG)+B Voltage Auxiliary battery voltage (BATT terminal) Over 8 V or Under 8 V Over 8 V: Auxiliary battery voltage 8 V or higher
Under 8 V: Auxiliary battery voltage below 8 VNumber of DTC Number of DTCs 0 to 255 0: Normal