Inspection [12/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT DIFFERENTIAL LOCK SWITCH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected (Differential Lock Switch) Standard Resistance
Tester Connection Condition Specified Condition 6 (L) - 9 (CPU) Differential lock switch on (Push) Below 1 Ω Differential lock switch off (Release) 10 kΩ or higher If the result is not as specified, replace the differential lock switch.
- Apply battery voltage between the terminals of the switch, and check the illumination condition of the differential lock switch.
Standard
Measurement Condition Specified Condition Battery positive (+) → Terminal 8 (ILL+)
Battery negative (-) → Terminal 7 (ILL-)Illuminates *a Component without harness connected (Differential Lock Switch) If the result is not as specified, replace the differential lock switch.
- Measure the resistance according to the value(s) in the table below.