Installation [12/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSTALL PURGE VALVE (PURGE VSV)
- Install the purge valve (purge VSV) to the No. 1 air cleaner hose.
- Connect the No. 2 fuel vapor feed hose to the purge valve (purge VSV) and slide the clip to secure it.
HINT:
Engage the clip within the area shown in the illustration.
*1 Fuel Vapor Feed Hose Assembly *2 No. 2 Fuel Vapor Feed Hose *a 2 to 7 mm (0.0787 to 0.276 in.) *b 120° *c Rear *d Upper *e Paint Mark - - - Connect the fuel vapor feed hose assembly to the purge valve (purge VSV) and slide the clip to secure it.
- Connect the purge valve (purge VSV) connector.
- INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY
Refer to PROCEDURE - Step 10 (INSTALLATION [12/2013 - 11/2015])
Refer to PROCEDURE - Step 10 (INSTALLATION [11/2015 - 11/2016])
Refer to PROCEDURE - Step 10 (INSTALLATION [11/2016 - ])
- INSTALL NO. 2 HOSE CLAMP BRACKET
- INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
Refer to INSTALLATION [12/2013 - ]