Inspection [12/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT THERMOSTAT
HINT:
The valve opening temperature is inscribed on the thermostat.
- Immerse the thermostat in water, and then gradually heat the water.
- Check that the valve of the thermostat opens at the specified temperature.
Standard Valve Opening Temperature
80 to 84°C (176 to 183°F)
If the valve does not open as specified, replace the thermostat.
- Check the valve lift.
*a Valve Lift Standard Valve Lift
10 mm (0.394 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.
- Check that the valve is fully closed when the thermostat is at low temperature (below 77°C (171°F)).
If not fully closed, replace the thermostat.