On-Vehicle Inspection [12/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT COOLING FAN MOTOR
- Disconnect the cooling fan motor connector.
- Check that the cooling fan motor operates smoothly when the battery is connected to the cooling fan motor connector.
*a Component without harness connected
(Cooling Fan Motor) - Measure the current while the cooling fan motor is operating.
Standard Current
Condition Specified Condition Battery voltage applied at 20°C (68°F) 13.6 to 19.6 A If the result is not as specified, replace the cooling fan motor.
- Connect the cooling fan motor connector.
- INSPECT NO. 2 COOLING FAN MOTOR
- Disconnect the No. 2 cooling fan motor connector.
- Check that the No. 2 cooling fan motor operates smoothly when the battery is connected to the No. 2 cooling fan motor connector.
*a Component without harness connected
(No. 2 Cooling Fan Motor) - Measure the current while the No. 2 cooling fan motor is operating.
Standard Current
Condition Specified Condition Battery voltage applied at 20°C (68°F) 13.6 to 19.6 A If the result is not as specified, replace the No. 2 cooling fan motor.
- Connect the No. 2 cooling fan motor connector.