Inspection [12/2013 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
- Measure the resistance according to the value(s) in the table below.
*a Valve Body Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 37 to 44 Ω 1 - Valve body Always 10 kΩ or higher 2 - Valve body If the result is not as specified, replace the vacuum switching valve assembly (for ACIS).
- Check the vacuum switching valve assembly (for ACIS) operation.
- When vacuum is applied to the port (E), check that air is sucked into the filter.
If the result is not as specified, replace the vacuum switching valve assembly (for ACIS).
*a Filter *b Port (E) *c Air - Apply battery voltage across the terminals. When vacuum is applied to the port (F), check that air is sucked into the port (E).
If the result is not as specified, replace the vacuum switching valve assembly (for ACIS).
*a Port (E) *b Port (F) *c Air
- When vacuum is applied to the port (E), check that air is sucked into the filter.
- Measure the resistance according to the value(s) in the table below.