DTC P0500: Vehicle Speed Sensor "A" [12/2013 - 11/2016]: Procedure
- READ VALUE USING TECHSTREAM (VEHICLE SPEED)
- Drive the vehicle and check whether the operation of the speedometer in the combination meter assembly is normal.
HINT:
- The vehicle speed sensor is operating normally if the speedometer reading is normal.
- If the speedometer does not operate, check it by following the procedure described for a speedometer malfunction.
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / ECT / Data List / Vehicle Speed.
Powertrain > ECT > Data List
Tester Display Vehicle Speed - Drive the vehicle.
- Read the value displayed on the Techstream.
OK
Vehicle speeds displayed on tester and speedometer display are equal.
Result
Proceed to OK NG
Result: 1
OK
SYMPTOM SIMULATION AND DTC CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2013 - 11/2016]
Result: 2
NG
See step 2
- Drive the vehicle and check whether the operation of the speedometer in the combination meter assembly is normal.
- CHECK COMBINATION METER ASSEMBLY (SPD SIGNAL WAVEFORM)
- Inspect the combination meter assembly using an oscilloscope.
*a Component with harness connected
(Combination Meter Assembly)- - - Move the shift lever to N.
- Jack up the vehicle.
- Turn the ignition switch to ON.
- Measure the voltage between the terminal of the combination meter assembly and the body ground while the wheel is turned slowly.
Standard Voltage
Tester Connection Condition Specified Condition F22-3 (+S) - Body ground Ignition switch ON Voltage generated intermittently HINT:
The output voltage should fluctuate up and down, similarly to the diagram, when the wheel is turned slowly.
Result
Proceed to OK NG
Result: 2
NG
GO TO METER / GAUGE SYSTEM (SPEED SIGNAL CIRCUIT). Refer to Speed Signal Circuit [12/2013 - 11/2015] Refer to Speed Signal Circuit [11/2015 - 11/2016]
Result: 1
OK
See step 3
- Inspect the combination meter assembly using an oscilloscope.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TCM)
- Disconnect the combination meter assembly connector.
- Disconnect the TCM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Tester Connection Condition Specified Condition F22-3 (+S) - C3-3 (SPD) Always Below 1 Ω Result
Proceed to OK NG
Result: 1
OK
REPLACE TCM. Refer to COMPONENTS [12/2013 - 11/2016]
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER ASSEMBLY - TCM)