Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
| The monitor will run whenever the following DTCs are not stored | P0712, P0713 (ATF temperature sensor circuit) P0115, P0117, P0118 (ECT sensor circuit) P0715, P0717 (Turbine speed sensor circuit) P0791, P0793 (Intermediate shaft speed sensor circuit) P0748 (Shift solenoid valve SL1 circuit) P0778 (Shift solenoid valve SL2 circuit) P0798 (Shift solenoid valve SL3 circuit) P2810 (Shift solenoid valve SL4 circuit) P2716 (Shift solenoid valve SLT circuit) P0327, P0328 (KCS circuit) P0120, P0121, P0122, P0123, P0220, P0222, P0223, P0604, P0606, P060A, P060B, P060D, P060E, P0657, P1607, P2102, P2103, P2111, P2112, P2118, P2119, P2135 (ETCS) U0100 (CAN communication system) |
| ATF temperature sensor circuit | Not circuit malfunction |
| ECT (Engine coolant temperature) sensor circuit | Not circuit malfunction |
| Turbine speed sensor circuit | Not circuit malfunction |
| Intermediate shaft speed sensor circuit | Not circuit malfunction |
| Shift solenoid valve SL1 circuit | Not circuit malfunction |
| Shift solenoid valve SL2 circuit | Not circuit malfunction |
| Shift solenoid valve SL3 circuit | Not circuit malfunction |
| Shift solenoid valve SL4 circuit | Not circuit malfunction |
| Shift solenoid valve SLT circuit | Not circuit malfunction |
| KCS (Knock control sensor) circuit | Not circuit malfunction |
| ETCS (Electronic throttle control system) | Not system down |
| CAN communication system | Not system down |
| Transmission range | "D" |
| Duration time from shifting "N" to "D" | 4 sec. or more |
| ATF temperature | -10°C (14°F) or higher |
| Engine | Starting |
| Input turbine torque | 100 N*m or more |
| Turbine speed | 250 rpm or more |
| Output speed | 250 rpm or more |