Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
P0717
| The monitor will run whenever the following DTCs are not stored | P0746, P0748 (Shift solenoid valve SL1) P0776, P0778 (Shift solenoid valve SL2) P0796, P0798 (Shift solenoid valve SL3) P2808, P2810 (Shift solenoid valve SL4) P0705 (Park/neutral position switch circuit) P07BF, P07C0 (Turbine speed sensor circuit) |
| Battery voltage | 8 V or higher |
| Ignition switch | ON |
| Starter | OFF |
| Shift change | Shift change is completed before starting next shift change operation |
| ECM selected gear | 2nd, 3rd, 4th, 5th or 6th |
| Output shaft rpm | 1000 rpm or more |
| R switch | OFF |
| NSW switch | OFF |
| Engine | Running |
| Transmission range switch circuit fail (P0705) | Not detected |
| Turbine speed sensor range check fail (P07BF, P07C0) | Not detected |
P07BF, P07C0
| The monitor will run whenever the following DTCs are not stored | P0717 (Turbine speed sensor circuit) |
| Battery voltage | 8 V or higher |
| Ignition switch | ON |
| Starter | OFF |
| Turbine speed sensor pulse input fail (P0717) | Not detected |