DTC B2342: Switch Failure [10/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Sliding Roof / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Sliding Roof > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Open Switch Failure(Past) Open switch failure signal (Past) ON or OFF ON: Sliding roof open switch failure signal (Past)
OFF: No sliding roof open switch failure signal (Past)- Close Switch Failure(Past) Close switch failure signal (Past) ON or OFF ON: Sliding roof close switch failure signal (Past)
OFF: No sliding roof close switch failure signal (Past)- Up Switch Failure(Past) Up switch failure signal (Past) ON or OFF ON: Sliding roof up switch failure signal (Past)
OFF: No sliding roof up switch failure signal (Past)- Down Switch Failure(Past) Down switch failure signal (Past) ON or OFF ON: Sliding roof down switch failure signal (Past)
OFF: No sliding roof down switch failure signal (Past)- Open Switch Failure(Current) Open switch failure signal (Current) ON or OFF ON: Sliding roof open switch failure signal (Current)
OFF: No sliding roof open switch failure signal (Current)- Close Switch Failure(Current) Close switch failure signal (Current) ON or OFF ON: Sliding roof close switch failure signal (Current)
OFF: No sliding roof close switch failure signal (Current)- Up Switch Failure(Current) Up switch failure signal (Current) ON or OFF ON: Sliding roof up switch failure signal (Current)
OFF: No sliding roof up switch failure signal (Current)- Down Switch Failure(Current) Down switch failure signal (Current) ON or OFF ON: Sliding roof down switch failure signal (Current)
OFF: No sliding roof down switch failure signal (Current)- Body Electrical > Sliding Roof > Data List
Tester Display Open Switch Failure(Past) Close Switch Failure(Past) Up Switch Failure(Past) Down Switch Failure(Past) Open Switch Failure(Current) Close Switch Failure(Current) Up Switch Failure(Current) Down Switch Failure(Current)
Result:
"OFF" appears on the Techstream screen
REPLACE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY (SLIDING ROOF ECU): REMOVAL [10/2015 - ]
Result:
"ON" appears on the Techstream screen
See step 2
- CHECK HARNESS AND CONNECTOR (SLIDING ROOF ECU - BODY GROUND)
- Disconnect the Q8 sliding roof drive gear sub-assembly (sliding roof ECU) connector.
- Disconnect the Q16 map light assembly (sliding roof control switch) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Q8-7 (OPN) - Body ground Always 10 kΩ or higher Q8-6 (DWN) - Body ground Always 10 kΩ or higher Q8-5 (CLS) - Body ground Always 10 kΩ or higher Q8-4 (UP) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- INSPECT MAP LIGHT ASSEMBLY (SLIDING ROOF CONTROL SWITCH)
- Remove the map light assembly (sliding roof control switch).
Refer to REMOVAL [10/2015 - ]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 16 (UP) - 20 (GND) UP switch is pressed Below 1 Ω 16 (UP) - 20 (GND) UP switch is not pressed 10 kΩ or higher 17 (DOWN) - 20 (GND) DOWN switch is pressed Below 1 Ω 17 (DOWN) - 20 (GND) DOWN switch is not pressed 10 kΩ or higher 7 (OPN) - 20 (GND) OPEN switch is pressed Below 1 Ω 7 (OPN) - 20 (GND) OPEN switch is not pressed 10 kΩ or higher 8 (CLS) - 20 (GND) CLOSE switch is pressed Below 1 Ω 8 (CLS) - 20 (GND) CLOSE switch is not pressed 10 kΩ or higher
Result:
OK
REPLACE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY (SLIDING ROOF ECU). Refer to DISASSEMBLY [12/2012 - ]
Result:
NG
REPLACE MAP LIGHT ASSEMBLY (SLIDING ROOF CONTROL SWITCH): REMOVAL [10/2015 - ]
- Remove the map light assembly (sliding roof control switch).