DTC P0A81-96: Hybrid/EV Battery Cooling Fan 1 Component Internal Failure [11/2015 - 12/2018]: Description
Refer to the description for DTC P0A81-11.
Refer to DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A81-96 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure | The battery cooling blower assembly is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.* *: This DTC is not stored when "Hybrid Battery Cooling Fan 1 Frequency" is excessively low or high. (1 trip detection logic) |
|
Does not come on | Master Warning Light: Comes on |
RELATED DATA LIST
| DTC No. | Data List |
|---|---|
| P0A81-96 |
|
The following items can be helpful when performing repairs:
Data List
- Hybrid Battery Temperature 1 to 3
- BATT Voltage
HINT:
"Hybrid Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly rotation speed.