Home >> Toyota >> 2018 >> Prius One >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System (Nickel Metal Hydride) - Diagnostic Codes (4 Of 9) >> HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) >> DTC P0C73-96: Motor Electronics Coolant Pump "A" Component Internal Failure [11/2015 -] >> DTC Summary

DTC Summary

  1. MALFUNCTION DESCRIPTION 

    This DTC is stored when the inverter water pump assembly is malfunctioning. The cause of this malfunction may be one of the following:

    Inverter water pump assembly malfunction 

    • Inverter water pump assembly internal malfunction
    • Open or short in wire harness
    • Improperly connected connector

    Hybrid cooling system malfunction 

    • Foreign matter in inverter water pump assembly
    • Hybrid cooling system coolant is frozen

    HINT: 

    If this DTC is stored, the driving torque may be restricted.