Combination Meter ECU Communication Stop Mode [11/2015 - ]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (COMBINATION METER ASSEMBLY MAIN LINE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G1-31 (CANH) - G1-32 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
Result:
NG
REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (COMBINATION METER ASSEMBLY MAIN LINE)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G1-20 (ET) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly) - Connect the cable to the negative (-) auxiliary battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition G1-21 (IG+) - Body ground Ignition switch ON (IG) 11 to 14 V G1-1 (B) - Body ground Ignition switch off 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Combination Meter Assembly)
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
Refer to REMOVAL [11/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.