Inspection [12/2013 - ]: Procedure
- INSPECT FUEL LID OPENER SWITCH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Fuel Lid Opener Switch)Standard Resistance
Tester Connection Condition Specified Condition 4 (B) - 1 (L) Pushed (ON) Below 1 Ω 4 (B) - 1 (L) Not pushed (OFF) 10 kΩ or higher If the result is not as specified, replace the fuel lid opener switch.
- Check that the switch illuminates.
- Measure the resistance according to the value(s) in the table below.