Pressure Sensor Circuit [03/2017 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)- Disconnect the A18 air conditioner pressure sensor connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A18-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V Result
Proceed to OK NG
Result:
NG
See step 6
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A18-1 (-) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
See step 5
Result:
OK
See step 3
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the K55 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A18-2 (PR) - K55-24 (PRE) Always Below 1 Ω A18-2 (PR) or K55-24 (PRE) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
*a Component with harness connected
(Air Conditioning Amplifier Assembly)- Measure the voltage with the following conditions met.MEASUREMENT CONDITION:
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch RECIRCULATION Interior temperature 25 to 35°C (77 to 95°F) NOTE:- If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
- It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
HINT:
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor with pulley will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.68 kPaG
Max.: 3294.37 kPaGActual refrigerant pressure displayed - Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor OK
The voltage and value displayed in the Data List change.
Result
Result Proceed to OK A NG (The voltage changes but the value displayed in the Data List does not change.) NG (The voltage does not change.) B
Result:
A
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [03/2017 - 06/2017] , or refer to REMOVAL [06/2017 - ]
Result:
B
REPLACE AIR CONDITIONER PRESSURE SENSOR. Refer to REMOVAL [03/2017 - 06/2017] , or refer to REMOVAL [06/2017 - 10/2020] , or refer to REMOVAL [10/2020 - ]
- Measure the voltage with the following conditions met.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the K55 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K55-3 (SG-4) - A18-1 (-) Always Below 1 Ω K55-3 (SG-4) or A18-1 (-) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [03/2017 - 06/2017] , or refer to REMOVAL [06/2017 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the K55 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K55-6 (S5-3) - A18-3 (+) Always Below 1 Ω K55-6 (S5-3) or A18-3 (+) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [03/2017 - 06/2017] , or refer to REMOVAL [06/2017 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR