Removal [03/2017 - 06/2017]: Procedure
- PRECAUTION NOTE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Refer to PRECAUTION [03/2017 - 06/2017]
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Refer to PROCEDURE - Step 2
- REMOVE COOL AIR INTAKE DUCT SEAL
Refer to PROCEDURE - Step 1
- REMOVE INLET AIR CLEANER ASSEMBLY
Refer to PROCEDURE - Step 20
- REMOVE E.F.I. VACUUM SENSOR ASSEMBLY (MANIFOLD ABSOLUTE PRESSURE SENSOR)
Refer to PROCEDURE - Step 1
- REMOVE V-RIBBED BELT
Refer to REMOVAL [03/2017 - ]
- REMOVE GENERATOR ASSEMBLY
- Disconnect the generator assembly connector.
- Open the terminal cap.
- Remove the nut and disconnect the wire harness from terminal B.
- Remove the bolt and separate the wire harness clamp bracket from the generator assembly.
- Remove the 2 nuts and loosen the bolt.
- Using an E8 "TORX" socket wrench, remove the 2 stud bolts.
- Remove the bolt and generator assembly.
- Disconnect the generator assembly connector.